Table of Contents
What is the column size for 2 storey building?
Column size for 2 storey (G+1) building:- For this general thumb rule, we will assume a structure of G+1 (2 storey) residential building, using standard 5″ walls, size of an RCC column should be 9”x 12” (230mm x 300mm) with 6 bars of 12mm Fe500 Steel with m20 grade of concrete and stirrups of T8@6″C/C.
How do you calculate columns?
Create a calculated column
- Create a table.
- Insert a new column into the table.
- Type the formula that you want to use, and press Enter.
- When you press Enter, the formula is automatically filled into all cells of the column — above as well as below the cell where you entered the formula.
How does RCC calculate column size?
RCC Column Size Calculation
- Square Column, Size of Column = √(79858) = 282.59 mm.
- Provide square column size = 285 mm x 285 mm.
- Ag = Provided = (285 mm x 285 mm) = 81225 mm2.
- Asc = Area of steel in concrete.
- = 0.01 Ag = 0.01 x 81225 = 812.25 mm2.
- Provide 8 nos. – 12 mm Dia.
- Ast (Area of steel) = 905 mm2.
- RCC Column Design.
What is the size of footing for 2 storey house?
Minimum Width of Concrete or Masonry Footings (inches) | ||
---|---|---|
Load-Bearing Value of Soil (psf) | ||
2-story | 25 | 13 |
3-story | 31 | 16 |
8-Inch Solid or Fully Grouted Masonry |
How do you calculate column strength?
How to Load Calculation on Column?
- Size of column Height 2.55 m, Length = 300 mm, Width = 600 mm.
- Volume of Concrete = 0.30 x 0.60 x 2.55 =0.459 m³
- Weight of Concrete = 0.459 x 2400 = 1101.60 kg.
- Weight of Steel (1%) in Concrete = 0.459 x 1% x 7850 = 36.03 kg.
How do I reduce column size in RCC?
Normally we use Fe415 and Fe500 grade of Steel in RCC column, having same axial capacity, we can reduce column size by increasing grade of Steel by using deform bar of Fe550D and Fe600 such like.
What is column length?
The length of the roadway occupied by a column or a convoy in movement. See also road space. Dictionary of Military and Associated Terms.
How to calculate the size of a column?
After which you can put the value of parameters in the factored load formula. This formula is used for calculating the size of the square, rectangular and circular column. The minimum size of the column should not be less than 230 mm x 230 mm.
How big should columns be in a building?
There are different types of columns such as timber columns, RCC columns, etc. Nowadays RCC columns are widely being used in structures, So in this article, I will discuss the sizes of RCC columns. The minimum size of a column should not be less than 9”x9” for single story structure with M15 (1:2:4) concrete.
How to calculate the column size in RCC?
RCC Column Size Calculation Square Column, Size of Column = √ (79858) = 282.59 mm Provide square column size = 285 mm x 285 mm Ag = Provided = (285 mm x 285 mm) = 81225 mm2
How big should a 3 storey column be?
Column footing size for 3 storey (G+2) building :- for 3 storey (G+2) house or in simple 3 floor building, general thumb rule, using standard 9″ thick walls, we recommended size of column footing should be 5’×5’×5′ (1.5m x 1.5m×1.5m) for isolated footing shallow foundation in gravel and sand soil with higher bearing capacity in which width